Vertical Laminar Sampling & Dispensing Booth

Among the exciting emerging value-engineered technologies are isolation and containment under sub turbulent ISO Class 5 (Fed Std 209E Class 100) SMCR is in the forefront, fully geared to render comprehensive support to the industry.

Containment systems are particularly useful for

  • Work with Active Process Ingredients
  • Powder weighing. Dispensing & sampling
  • Work with cortico steroids
  • Work with low toxic or otherwise low risk hazardous materials.

Sampling, specially substances that are either hazardous or of unknown origin

The new concept is to use a “Sampling booth” that effectively controls the average airborne dust with in the area. For details on “Sampling booth” refer Drawing.

We expertise in point-source containment and in the precise control of particles in an air stream is reflected in the patented features of our down flow booths, sampling stations, and customized workstations. Laminar Flow booths achieve extremely low exposure levels without restricting the operator’s movements. Modular design allows quick and simple installation. Stainless steel construction provides durability and appearance.

The Laminar Flow from the HEPA plenum effectively contains dust at source while dispensing. It is clearly evident that air borne dust if any will be drawn in through the pre-filter in the reverse flow booth and will be recycled though HEPA before being delivered. The operator is clearly protected as the dust propels away from his breathing zone.

Our Sub-Turbulent Flow Systems for Product Sampling and Dispensing are designed as Open Front Containment Systems with built-in scavenging arrangements that draw powder aerosols away from the operator and the operating environment, protecting product and personnel.

Specifications:

Body Stainless Steel bulkhead or laminated double walled insulated side panels/ CRCA powder coated/ SS 304/ 316 – Modular Construction
Blower (AHU) 1400rpm, 1Ø, ¼ Hp, Dynamically and statically balanced, Variable Speed, High performance, Noise abated, dynamically balanced impellers
Filters Two HEPA 0.3 microns, 99.97% efficiency, micro glass fiber media (imported) banks – the main bank configured for continuous clean – down of work space and bleed filters comprising the extract bank configured for 10% displacement
Two stage pre-filter assemblage for multi-disperse particles predominantly in the size range of 5-20 microns. Pre – 10/5 micron, 99% efficiency, non-woven synthetic fiber media
Shield Anti-drag Shield at the entry side (Vinyl/ Transparent – Flexi Curtains)
Protective grills CRCA Powder Coated/ SS 304 with maximum open area.
Flow Vertical
Magnehelic Provided to check the pressure drop across the filters.
Lighting Fluorescent lighting
Electrical 220 Volts, 1Ø, 50Hz, with 2 nos. of 5amp. switch socket (Combined)
Velocity 90 + 20fpm
Noise level Less than 65 db on ‘A’ scale
Leveling jacks Positioning and leveling the equipment
Cleanliness LF-DS models exceed CLASS-100 (US federal Standard 209 E and ISO-Std. 14644-1).
Optional UV, Castor Wheels

Sizes:

Models Filter Area External (Overall Size)
Vertical
LF- DS – 1200/ 600 4’W x 2’D 4’.3”W x 5’D x 7½’H
LF- DS – 1200/ 1200 4’W x 4’D 4’.3”W x 7’D x 7½’H
LF- DS – 1800/ 1200 6’W x 4’D 6’.3”W x 7’D x 7½’H
Products are customizable according to requirements